HID EDGE EVO EHR40-K Controller/Reader and Module

twitterX_W twitterX_W twitterX_W twitterX_W twitterX_W

Properties

  • Model (and Part #): EHR40-K (82120CKI0001A)
  • Mounting Holes: US Single-gang and EU / APAC 60mm
  • Dimensions - EHR40: 3.3" W x 4.8" H x 1.2" D (83.9 mm x 122.2 mm x 30.5 mm)
  • Dimensions - EDM-M: 3.3" W x 5.0" H x 1.5" D (84.0 mm x 127.0 mm x 37.0 mm)
  • Weight - EHR40: 6.3oz (180g)
  • Weight - EDM-M: 4.9oz (140g)
  • Operating Temperature: 32° to 122° F (0° to 50° C)
  • Operating Humidity: 5% to 95% relative, non-condensing
  • Communication Ports: Ethernet (10/100), Hi-O CANbus
  • 13.56 MHz Card Compatibility: 13.56 MHz iCLASS HID Application, ISO14443A CSN
  • Warranty: Warrantied against defects in materials and workmanship for 18 months (See complete warranty policy for details).
  • DC Input (MAX) @ PoE: 14.4W (300mA @ 48VDC)
  • DC Input (MAX) @ AUX +12VDC: 18W (1500mA @ 12VDC)
  • DC Input (MAX) @ AUX +24VDC: 36W (1500mA @ 24VDC)
  • Supervised Inputs Power (MAX): 0.025W (5mA sink, 5V nominal) 0 to +5VCD Ref
  • DC Input @ PoE: 8W
  • DC Input @ AUX +12VDC: 13.1W
  • DC Input @ AUX +24VDC: 26.6W
  • Hi-O CANbus Output Voltage, DC Input = PoE: 24VDC
  • Hi-O CANbus Output Voltage, DC Input = AUX: AUX +VDC

Description

Interface to standard door – REX, DPS and lock

Enabling cost effective installation and high performance access control functionality, the EDGE EVO® EHR40-K Controller/Reader and Interface Module package is a single-door access control panel with reader and separate discrete door interface. The controller/reader is installed at the door and the Hi-O Interface Module is mounted separately in a secure location.

Additional highlights:

  • The controller/reader and module are connected using the secure Hi-O bus and the Hi-O module provides interface to four discrete inputs and two outputs.
  • An additional Hi-O iCLASS® reader can be attached to the EHR40-K controller/reader's Hi-O bus for in/out reading.
  • The EHR40-K will accept either a second Hi-O iCLASS reader using the Hi-O bus or a Wiegand /Clock-and-Data reader through the use of a Wiegand Hi-O interface module.

The integrated EDGE EVO® EHR40-K Controller/Reader also offers interface to 13.56 MHz compliant credentials, including iCLASS.