HID® Proximity ProxPro® II 5455
Category HID Proximity
Brand HID

HID's ProxPro® II proximity reader for access control combines performance, reliability, and ease of installation into a two-piece, weatherproof potted enclosure. International users will appreciate the multilingual installation manual, lower voltage requirement and flexible mounting options

  • Ideal for medium-range applications
  • Available with Wiegand or Clock-and-Data interface
  • Optional glass mount kit available for mounting the reader behind glass
  • Potted reader suitable for indoor or outdoor use
  • Available in black, white, gray or beige
  • 18" (45 cm) wire pigtail standard; consult factory for 9' (2.7 m) pigtail available by special order


Key Features

  • Two-piece reader design allows for easy installation
  • Available with a Wiegand or Clock-and-Data interface
  • Provides high reliability, consistent read range and low power consumption
  • Features include multicolor LED and internal control or host control of the LED and beeper
  • Mounts directly on metal with minimal impact on the read range performance. Optional kit enables mounting behind glass
  • Compare features of the ProxPro II to the original ProxPro reade
  • Typical Maximum Read RangeProxCard® II Card - up to 9" (22 cm)
    ISOProx® II Card - up to 8" (20 cm)
    DuoProx® II Card - up to 8" (20 cm)
    Smart ISOProx® Card - up to 8" (20 cm)
    Smart DuoProx® Card - up to 8" (20 cm)
    HID Proximity and MIFARE® card - up to 8" (20 cm)
    ProxCard® Plus Card - up to 4" (10 cm)
    ProxKey® II Keyfob - up to 4" (10 cm)
    MicroProx® Tag - up to 4" (11 cm)

    *Depending on local installation conditions

    Dimensions
    5.00" x 5.00" x 1.00" (12.7 x 12.7 x 2.54 cm)

    Power supply
    5-16 VDC
    Linear power supplies are recommended

    Cable Distance
    Wiegand interface: 500 feet (150 m)
    Clock-and-Data interface: 50 feet (15 m)
    Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control

    Current Requirements
    Average: 25 mA at 12 VDC
    Peak: 125 mA at 12 VDC

    Operating Temperature
    -22º to 150º F (-30º to 65º C)

    Operating Humidity
    0-95% relative humidity non-condensing

    Weight
    13.6 oz. (385 g)

    Certifications
    Canada/UL 294 Listed
    FCC Certification, United States
    Canada Certification
    CE Mark
    EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety)
    Fifteen EU Countries under the R&TTE Directive (EN300 330 - SRD, and ETS 300 683 - EMC)
    Australia C-Tick (pending)
    New Zealand (pending)
    Taiwan (pending)

pdfs